Electrical Thermography for Data Centers

Critical power paths. Clear thermal findings.

Maintaining an uninterrupted electrical supply requires reliable information about equipment condition. We inspect accessible power paths in your data center under suitable load and assess thermal anomalies for operations and maintenance teams.

Discuss your inspection

For critical facilities teams, operators and technical service providers

Electrical distribution equipment and server racks – illustrative industry scene
Illustrative industry scene · not a documented client inspection

The task

See the power supply in context.

Redundancy alone reveals little about the thermal condition of individual connections. An agreed inspection scope makes clear which power paths have been covered and where insufficient load, obstructed views or restricted access limit the assessment.

What we inspect

Typical inspection scope.

The precise scope depends on your equipment and the task we agree together.

01

Switchgear & distribution

Accessible medium- and low-voltage switchgear, transformer connections, main distribution boards and sub-distribution boards.

02

UPS & bypass paths

Loaded connections, switching components and busbars along the agreed power supply paths.

03

Technical infrastructure

Electrical equipment in technical areas, plus targeted follow-up inspections after remedial work.

Before the visit

Good results start
with good planning.

Thermography records the temperature distribution of visible surfaces. Load, surface properties and the surrounding conditions affect what can be concluded.

Operating conditions
Agree representative loads and current switching arrangements with your operations team. Redundant paths carrying no load have limited diagnostic value.
Safe access
Plan site access, escort requirements, the necessary permits and any removal of covers by authorized, qualified electrical personnel.
Report structure
Agree asset identifiers, site structure, confidentiality requirements and the preferred report language in advance.

What you receive

Findings you
can act on.

You receive findings linked to the agreed power paths, an assessment of how urgently action is needed, and a clear record of any inspection gaps. This supports coordination between operations, electrical maintenance teams and service providers.

  • Visible-light and thermal images with clear asset identification
  • Technical assessment and recommendations for next steps
  • Recorded measurement conditions and inspection limitations
How the documentation is structured

Good to know

Before we start.

We are happy to discuss any other questions with you.

Does the data center need to be shut down?

No. The equipment being inspected must be operating during our measurements. The thermographic measurements themselves do not require a shutdown.

Do you cover our site?

Our service area covers all of Germany, with clients from Passau to Flensburg. With flexible scheduling, we can combine several client visits in the same region and offer lower travel costs. We have locations in Würzburg, Bonn, and Berlin.

Can we discuss our project in English?

Yes. You are welcome to send your inquiry in English. We agree the inspection scope, site arrangements and report language before the visit.

What are the limits of the inspection?

A thermal image without a visible anomaly does not prove that an installation is free of faults. Concealed, obstructed or insufficiently loaded components can only be assessed to a limited extent. Thermography complements other required inspections.